What Are the Electrical Requirements for a Caravan Park or Holiday Park in Sydney?

Caravan and holiday parks in Sydney must meet AS/NZS 3001.1 for site supplies, with RCD protected pillars, a properly sized switchboard and safe reticulation between sites. This guide covers what park operators and property managers need to check.

What are the electrical requirements for a caravan park or holiday park in Sydney? A caravan park or holiday park has to meet AS/NZS 3001.1, the Australian Standard covering site supplies for connectable electrical installations, on top of the general wiring rules in AS/NZS 3000. In practice that means a dedicated, individually metered and RCD protected supply pillar at every site, a main switchboard and submains sized for the whole park's maximum demand, and safe overhead or underground reticulation between sites.

This is a genuinely different job to wiring a single caravan, tiny home or motorhome, which falls under AS/NZS 3001.2 and is the homeowner level guide we cover in our caravan, tiny home and motorhome electrical rules post. This guide is written for park owners, operators and property managers responsible for the park's own infrastructure, not for a single occupier plugging in for a weekend.

⚡ Quick Answers: Caravan Park Electrical Requirements

  • What standard applies to a park's own electrical supply? AS/NZS 3001.1 covers site supplies for connectable electrical installations, which is the park operator's side of the fence.
  • Does every site need its own RCD? Yes, each supply pillar needs residual current device protection, matched to the socket outlets and lighting on that site.
  • Who is responsible for the pillar versus the van's own wiring? The park owns and maintains the supply pillar and the submains feeding it, while the occupier is responsible for their own van's internal wiring under AS/NZS 3001.2.
  • Can an existing park be rewired without shutting down? Usually yes, with staged upgrades across sections of the park and temporary supply arrangements, but it needs careful planning with a licensed electrician.
  • Is this Level 2 ASP work? The service and consumer mains feeding the park's main switchboard are, since that is the connection point to the Ausgrid or Endeavour Energy network.
  • Is a holiday park treated differently to a caravan park for electrical purposes? No, the same electrical standards apply regardless of how the site is zoned or marketed to guests.

1. Site supply pillars and individual metering

Every occupied site in a caravan or holiday park needs its own weatherproof supply pillar, fitted with a socket outlet rated for the site's expected load, RCD protection and, in most modern parks, its own meter or sub meter. AS/NZS 3001.1 sets out how these pillars are built, positioned and protected so a guest can plug in a caravan or motorhome safely without ever touching the park's own wiring.

Pillars also need to be spaced and positioned so cables from the site to the van are not a trip hazard, and so a vehicle reversing onto a site cannot damage the pillar itself. Older parks built before these rules tightened up often have pillars that are undersized, poorly earthed or missing RCD protection altogether, which is one of the most common issues we find during a park wide electrical safety inspection.

2. Switchboard and submain capacity for the whole park

The park's main switchboard has to be sized for the realistic maximum demand of every site running air conditioning, cooking appliances and charging at once, not just the average load. Get this wrong and the result is nuisance trips, voltage drop at the far end of the park, or a switchboard that cannot safely take on more sites later.

A switchboard upgrade for a park almost always involves resizing the submains that feed each cluster of pillars as well as the main board itself, since adding capacity at one end does nothing if the cable feeding a distant section of the park is already running close to its limit. This is also the point where a power supply upgrade from the network may be needed if the park's existing connection simply cannot carry the extra load.

3. RCD and safety switch coverage across all sites

Every supply pillar's socket outlets need RCD protection, and larger parks typically split RCD coverage across several switchboards rather than one single device for the entire site, so a fault on one pillar does not take out power to every guest at once. Camp kitchens, amenities blocks and laundries need their own RCD protected circuits too, given how much of that equipment sits in genuinely wet areas, and every switchboard across the park should carry clear, up to date switchboard labelling so staff and contractors can isolate the right circuit quickly in an emergency.

Testing this protection regularly matters more in a caravan park than almost anywhere else, since the equipment plugged in changes every few days and the outdoor pillars are exposed to weather, insects and the occasional reversing vehicle. A scheduled electrical safety inspection picks up a failed RCD or a damaged pillar before a guest finds out the hard way.

4. Overhead versus underground reticulation

Reticulation is the network of cable running between the park's main switchboard and every supply pillar. Older parks are often wired overhead on poles strung between sites, which is cheaper to install but more exposed to storm damage, falling branches and the wear that comes with decades of coastal or bushland weather around Sydney.

Newer parks, and most parks doing a staged upgrade, move to underground service mains for at least the main distribution runs, since buried cable is far less likely to be damaged by a tree branch or a tall caravan clipping an overhead line. Where overhead reticulation stays in place, our overhead service mains installation team checks clearances and cable condition as part of any park wide inspection, since overhead service span and cable size rules set out exactly how much clearance and what cable rating a sagging or damaged span needs before it is compliant again.

5. Amenities blocks, camp kitchens and shared facilities

Amenities blocks, camp kitchens, laundries and any shared recreation building in the park are treated as their own electrical installations under AS/NZS 3000, separate from the site supply pillars covered by AS/NZS 3001.1. These buildings sit in genuinely wet, high traffic areas, so RCD coverage, equipotential bonding around showers and laundry equipment, and adequate lighting for guests walking around at night all need to be checked on their own merits.

A lot of older parks have amenities blocks that were wired decades ago and simply have not kept pace with how much equipment guests now bring, from hair dryers to laptop chargers to portable heaters in winter. Upgrading these circuits alongside the site pillars, rather than treating them as an afterthought, is usually the more cost effective approach.

6. Expanding or rewiring an existing park without shutting down

Most parks cannot afford to close entirely for an electrical upgrade, so staged work is the norm. A typical approach splits the park into sections, upgrades the switchboard and submains feeding one section at a time, and uses temporary supply arrangements so occupied sites are never left without power overnight. This takes careful planning with your electrician well before the first site is touched, including confirming what the network operator will allow for any temporary connections during the works.

If the park is adding new sites, or converting a section from long stay to short stay guests with higher expected loads, the maximum demand calculation needs to be redone for the whole park, not just the new section, since the main switchboard and the service feeding it both need to handle the combined total.

7. Embedded networks and submetering

Many larger parks run as an embedded network, buying bulk electricity from Ausgrid, Endeavour Energy or Essential Energy and on selling it to individual sites through submeters, rather than every guest having their own retail account. If your park is considering this or already runs one, our smart meter upgrades service covers the individual site metering side, while the park's own bulk connection and any network application still needs to go through the distributor directly. If you are not sure which network your park actually sits on, you can check your network area in seconds with our postcode checker before lodging anything.

Why it's Level 2 ASP work

The service mains and consumer mains feeding a caravan park's main switchboard connect directly to the Ausgrid or Endeavour Energy network, and that connection point is restricted work under the relevant electrical safety rules. Only an accredited Level 2 ASP can safely disconnect, reconnect or upgrade that connection, request a new or upgraded network supply, or carry out work on consumer mains feeding the main switchboard. Everything downstream of the main switchboard, including the submains to each pillar, still needs a licensed electrician, but it does not require Level 2 ASP accreditation specifically unless it touches the network connection itself.

How High Demand Electrical helps

High Demand Electrical is one of Sydney's most trusted Level 2 ASPs, and we have worked on caravan and holiday parks across Sydney's West, South West and Sutherland Shire, from a single section rewire to a full site wide switchboard and pillar replacement program. We size the main switchboard and submains for the park's real maximum demand, not just today's occupancy, plan staged works so sites stay powered throughout, and handle the Level 2 ASP side of any new or upgraded network connection directly with Ausgrid or Endeavour Energy. As a licensed local team, not a call centre, we can usually get someone on site to scope the job properly before any pricing is locked in.

Caravan Park Electrical Requirements FAQs (Sydney)

Does every individual caravan site need a separate meter?

Not always. Some parks meter every site individually, while others run an embedded network with submetering, or simply include power in the site fee without separate metering at all. See smart meter upgrades for how individual site metering is usually added or upgraded.

Who pays for a faulty supply pillar, the park or the guest?

The supply pillar and everything feeding it is the park's own electrical installation and the park's responsibility to maintain, regardless of who is parked at that site at the time.

Can we add more powered sites to an existing park?

Usually yes, but the main switchboard, submains and the park's overall network connection all need to be checked against the new combined maximum demand first. See power supply upgrades for how this is assessed.

How often should a caravan park's electrical system be inspected?

Given how much the plugged in load changes from week to week and how exposed outdoor pillars are, an annual electrical safety inspection across the whole park is the safest approach, more often if the park operates year round.

Is overhead reticulation still allowed in a Sydney caravan park?

Yes, overhead reticulation is still permitted, though most parks doing a staged upgrade choose to move key runs underground where practical, since buried cable is less exposed to storm and vehicle damage.

Get Your Caravan Park Electrical Quote

If your caravan park or holiday park needs a switchboard upgrade, new supply pillars or a full site wide electrical safety inspection, get a switchboard upgrade quote from High Demand Electrical or call 0402 559 777 to talk through your park's layout. Every job like this needs a proper site assessment before we can confirm scope or pricing, since every park's existing wiring and occupancy pattern is different.

Need Help Fast?

Choose your issue to get expert solutions, upfront pricing, and clear next steps—or speak with a local electrician today.
Emergency Electrician Near Me
Public Holiday Electrician
Weekend Electrician
After Hours Electrician
Emergency Consumer Mains
Cut Underground Cable
Underground Power Fault
Service Line Pulled Off House
Tree On Power Lines
Low Hanging Power Lines
Fallen Power Line
Power Pole Hit By Car
Leaning Power Pole
Fallen Power Pole
Power Surge Damage
Lightning Strike Damage
Storm Damage Meter Box
Storm Damage Switchboard
Flood Damage Electrical Repairs
Storm Damage Electrician
Lights Flickering
Fuse Keeps Blowing
Safety Switch Keeps Tripping
Circuit Breaker Keeps Tripping
Main Switch Won't Reset
Burnt Meter Box
Smoke Coming From Meter Box
Emergency Switchboard Repairs
Buzzing Switchboard
Smoke Coming From Switchboard
Sparking Switchboard
Burning Smell From Switchboard
Electrical Fault Finding
Power Restoration
Power Restored But No Power
Partial Power Loss
No Power to House
Power Outages

Follow Us On Our Social Media

Powering Your Needs with Expertise

If you’re looking for a reliable, experienced, and prompt electrician, look no further than High Demand Electrical. We cater to all your electrical needs, from routine maintenance to emergency repairs and complete system installations. Our skilled team is committed to providing professional service that ensures your electrical systems run smoothly. Whether it's a small task or a large project, give us a call today. Let us meet all your electrical demands with the quality and reliability you deserve.